Cable Manufacturer Case Study: 1,500 V DC for Solar and Storage
Case Details
Cable Manufacturer Case Study: 1,500 V DC for Solar and Storage
A solar and storage EPC had a grid connection date already in the contract and 620 kilometres of DC cable to buy into a rising copper market. The risk was not finding a supplier; it was holding a price and a delivery date long enough to get the containers on the water. We booked the copper against the order and shipped in three waves, and the last container landed before the energisation window.
Project Snapshot
|
Item |
Detail |
|
Client |
Solar and storage EPC procurement manager |
|
Site |
180 MW solar array with 60 MWh of battery storage |
|
Project |
DC array cable, battery-to-inverter cable and earthing supply |
|
Products |
1,500 V DC solar cable, armoured AC cable, aerial bundled cable |
|
Material and finish |
Tinned copper conductor, cross-linked insulation, LSOH sheath |
|
Load range |
4 mm² and 6 mm² DC conductors, 90 °C continuous rating |
|
Factory lead time |
18 working days from order confirmation |
|
On-site time |
3 shipment waves across the construction programme |
|
Outcome |
46 containers delivered ahead of the energisation window |
The Problem: A Fixed Date and a Moving Metal Price
Cable is bought on a metal price and delivered months later. On a project this size, copper is the largest single line in the cable package, and the quote that wins the order is often the one that cannot be honoured when the metal moves.
The EPC's problem was sequencing. The DC array cable had to land before the tracker crews finished, the battery-to-inverter cable had to land before the containerised storage arrived, and both were tied to a grid date with a penalty attached.
There was a technical constraint too. This was a 1,500 volt DC system with battery storage alongside it, so the cable needed DC ratings, sunlight and ozone resistance, and a low smoke halogen free sheath for the battery enclosures.
Why We Chose a Booked Metal Position Over Spot Buying, Aluminium and Split Sourcing
Buy copper at spot on the day of each production run. Excluded. It exposes the whole package to the market, and the EPC needed a number it could put in the project budget.
Move the DC runs to aluminium conductor. Excluded. It needs a larger cross section and a re-validation of every connector and termination, which is a schedule risk on a site already under pressure.
Split the package across three suppliers to spread the risk. Excluded. Three suppliers means three inspection regimes and three shipping schedules, and the EPC wanted one document set.
Book the metal against the order and ship in waves against the site programme. Selected. The price is fixed, and the waves follow the construction sequence.
The Cable We Manufactured
DC array cable was supplied with tinned copper conductors in 4 mm² and 6 mm², cross-linked insulation rated for continuous operation at 90 degrees Celsius, and a sheath tested for sunlight and ozone resistance. The TUV certification our range holds against IEC 62930:2017 is the reference the EPC's engineer asked to see.
Battery-to-inverter runs and the AC collection side took armoured power cable, because those circuits run in cable trenches and need mechanical protection. Site distribution and the temporary construction supply used aerial bundled cable on poles, which is faster to install than trenched cable across a site this size.
The medium voltage side was quoted from the same XLPE insulated range, so the EPC dealt with one inspection regime and one document set across the whole package.
Installation: How the Shipment Ran
Production was released in three waves rather than in one run, and each wave was built to a construction sequence rather than to a container count.
Wave one was the DC array cable, sized to the first tracker block. Wave two was the battery side, released when the storage containers were confirmed. Wave three was the AC and medium voltage cable for the substation end.
Metal was booked against the order at confirmation, which is what let the quoted price survive a market that moved during production. Each wave was inspected and released separately, so documentation for one wave did not hold up another.
Testing and Quality Control
Every batch is inspected before release, and the testing runs in the group's own CNAS-accredited laboratory rather than being outsourced. Conductor resistance, insulation thickness, sheath thickness and the voltage withstand test are recorded per drum.
Insulation and sheath compounds are checked for the properties the DC rating depends on, and the finished cable is tested for flame spread and for smoke and acid gas behaviour where the specification calls for LSOH. Drum lengths are verified, because a short drum on a long array run is a splice the design did not allow for.
Each drum carries a tag with the batch number and the test record, which is the document the site engineer checks before the cable is pulled.
Results: What the Numbers Show
All 46 containers shipped in three waves and landed ahead of the energisation window. The quoted price held through production because the metal was booked at confirmation, which is the part of the package the EPC had been most exposed on.
Defects at the site gate ran below the level the project had allowed for, and no drum was rejected on length. The commissioning team pulled and terminated the DC runs inside the sequence planned, and the grid date held.
The EPC has since quoted the same arrangement on a second site, with the 33 kV armoured supply as the reference for the collection network.
What This Case Means for Your Project
On a large cable package, the two things that go wrong are the metal price and the drum length. Both are controllable if they are dealt with at order stage rather than at delivery.
Send us your single line diagram, the conductor sizes and your energisation date. We will quote with the metal position stated, build to your construction sequence rather than to container fills, and ship with the test record on every drum. You can brief our project desk on the schedule directly.