CU / Mica Tape Fire Resistant Cable For Sprinkler Smoke Control System NH-YJV
CU / Mica Tape Fire Resistant Cable For Sprinkler Smoke Control System NH-YJV
CU / Mica Tape Fire Resistant Cable For Sprinkler Smoke Control System NH-YJV
Engineers at Shanghai Shenghua Power Group Cable have engineered CU/Mica Tape Fire Resistant Cables to outlast infernos—ensuring critical systems keep operating even at 950°C for 90+ minutes.
Product Information
Number Of Cores:
1 Core, 2 Cores, 3 Cores, 4 Cores, 5 Cores
Standard:
IEC 60502-1, IEC 61034, IEC 60754
Screen:
Mica Tape
Type:
Low Voltage
Size:
1.5-800 mm²
Long-term Temperature:
90°C
Model Number:
NH-YJV
facebook
line
Whatsapp
Pinterest
Tumblr
Linkedin

​​Triple-Shielded Fire Defense: The Shenghua Engineering Standard​​

  1. ​​Mica Firewall Core​​:

    • Copper conductors wrapped in ​​mica tape​​ resist temperatures up to ​​800°C​​, preventing conductor exposure during prolonged fires—exceeding IEC 60331 and BS 6387 standards 
       
    • Unlike standard cables, mica maintains circuit integrity for sprinklers and smoke exhaust fans when flames engulf conduits.
  2. ​​XLPE + LSZH Armor​​:

    • ​​XLPE insulation​​ withstands ​​90°C continuous heat​​ and ​​250°C short-circuit spikes​​ (5 seconds), outperforming PVC’s 70°C limit while resisting electrical degradation 
    • ​​Zero-halogen LSZH sheathing​​ reduces toxic smoke to ​​<0.5% HCl​​ (IEC 60754-1) and ensures ​​>60% light transmittance​​ (IEC 61034), critical for evacuation visibility 
  3. ​​Mechanical Resilience​​:

    • Steel tape armoring (e.g., SC1-FPB-CE2 models) protects against falling debris and water spray during firefighting 
       
    • Cold-climate flexibility: Preheating enables installation at ​​-30°C​​, with operational stability from ​​-40°C to 90°C​​ 
       

​​Certified for Global Critical Infrastructures​​

Shenghua’s cables comply with post-Grenfell EU/UK regulations, including:

  • ​​CPR Euroclass B2ca​​: 40% lower smoke emission than minimum requirements 
     
  • ​​BS 7671 Amendment 2​​: Mandatory for UK fire safety systems 
     
  • ​​IEC 60331 & EN 50200​​: Validated 90-minute circuit integrity (PH 120 rating) 

 

  • ​​Certifications​​: CE, RoHS, CCC, KEMA (third-party verified) 
     

​​Technical Specifications: Shenghua Fire Resistant Cables​​

Model Code Voltage Cores Section Area (mm²) Armoring Key Application
SC1-FPB-CE 0.6/1kV 1-5 1.5-400 No Sprinkler controls
SC1-FPB-CE2 0.6/1kV 1-5 1.5-400 Yes Tunnel smoke systems
SC1A-CTE 450/750V 4-61 1-2.5 No Emergency lighting
​​Bending Radius​​ Single-core: 20× diameter Multi-core: 15× diameter
2
   

All models feature color-coded cores (Red/Black/Blue/White + Green/Yellow earth) for error-proof installation.


​​Applications Where Failure Is Not an Option​​

  • ​​High-Rise Buildings​​: Powers smoke extraction fans and sprinkler pumps (e.g., London skyscraper retrofit with SC1-FPB-CE2).
  • ​​Tunnels & Metros​​: Ensures emergency lighting stays on during evacuations (LSZH sheathing reduces smoke obscuration) 
     
  • ​​Hospitals/Airports​​: Maintains fire alarm functionality for 90+ minutes (IEC 60331-certified) 
     

​​Why Global Engineers Choose Shenghua​​

  • ​​30+ Years of Expertise​​: China’s #2 cable manufacturer (13B RMB revenue, 600 engineers) with IEC/BS-certified production 
     
  • ​​Rigorous Testing​​: On-site fire labs validate performance under BS 6387 Category CWZ (fire + water + mechanical shock) 
     
  • ​​Global Supply​​: 15-day delivery from Shanghai hubs to EU/ASEAN sites 
     

 

Application
These cables are installed to supply power to building essential services including fire alarms,
sprinkler control system, emergency and evacuation lighting and smoke control systems,
such as high rise buildings and apartments, airports, shopping centres, cinemas and road and rail tunnels
 
Constructions
Conductor: Class 1/2 Plain annealed copper wires, solid or stranded, with mica tape wound
Insulation: XLPE or LSZH compound
Sheath: LSZH compound
Core color: red, black, blue, white for active core, green/yellow for earth core, orange or red or black for sheath
 
Technical data
Rated voltage: 0.6-KV
Max. Conductor Temp.: Normal (90°C), short circuit no more than 5 s (the highest temperature of conductor shall no more than 250°C )
Min. Ambient Temp.:The cable shall be pre heated if the ambient temperature is below 0°C
Min. Bending Radius: Single core cable 20(d+D)±5%
                                      Multi-core cable 15(d+D)±5%
 
Certificates
CE, RoHS, CCC, KEMA and more others at request
 
Product code 

SC1-FPB-CE XLPE insulated halogen-free polyolefin sheathed safe & clean fire-proof cable
SC3-FPB-CV XLPE insulated low-halogen PVC sheathed safe & clean fire-proof cable
SC1-FPB-CE2 XLPE insulated steel tape armored halogen-free polyolefin sheathed safe & clean fire-proof cable
SC3-FPB-CV2 XLPE insulated steel tape armored low-halogen PVC sheathed safe & clean fire-proof cable

 
Code designations

S Safe
C Clean, Low smike, zero halogen
1 or 3 Flame resistant class as per GA306.1-2001
A or C Flame resistant type A or C
FP Fire proof
B
Recommended products