In high-risk environments like hospitals, metro tunnels, and petrochemical plants, circuit integrity during fires is non-negotiable. Shanghai Shenghua Power Group Cable addresses this with its FRC 4-Core LSOH Fire Resistant Cables—designed to maintain power transmission even at 1,000°C for 90+ minutes while emitting zero toxic smoke.
Core Technology: Triple-Layer Fire Defense
- Mica Tape Firewall: Wrapped around copper conductors, mica tape withstands 250°C during 5-second short circuits and 750°C+ in prolonged fires, preventing conductor exposure and ensuring circuit integrity
- LSOH Insulation & Sheath: Halogen-free materials reduce toxic gas emissions (HCl <0.5%) and smoke density (>60% light transmittance), aligning with IEC 61034-2 and IEC 60754-1
- XLPE Thermal Stability: Cross-linked polyethylene insulation enables long-term operation at 90°C, outperforming PVC’s 70°C limit while resisting electrical degradation
Certified Performance for Global Compliance
Shenghua’s cables exceed international safety benchmarks:
- Standards: IEC 60502, 60331 (fire resistance), 61034 (smoke density), and GB/T 12706 (China)
- Certifications: CE, RoHS, CCC, and KEMA-tested reliability
- Fire Ratings: Class ZA/ZB/ZC/ZD flame retardancy and 950°C fire resistance for emergency systems
Installation & Durability Optimized
- Bending Flexibility: Multi-core cables require only 15× outer diameter bends, easing installation in tight spaces
- Environmental Resilience: Operates at -0°C to 90°C (preheating below 0°C) and resists chemicals, oils, and mechanical stress
- Water & Impact Resistance: Withstands sprinkler systems and falling debris during fires—critical for evacuation safety
Applications Where Failure Is Not an Option
- High-Rise Buildings: Powers fire lifts, smoke control, and emergency lighting (e.g., NH-YJV32 variant)
- Power Stations & Petrochemical Plants: Ensures uninterrupted operation of critical control systems
- Metro Tunnels: LSOH properties aid visibility during evacuations
Technical Specifications
| Cross-Section (mm²) | Outer Diameter (mm) | Weight (kg/km) | Max. DC Resistance (Ω/km) | Current Rating (Air) |
|---|---|---|---|---|
| 4×1.5 | 14.4 | 241 | 12.1 | 20A |
| 4×120 | 52.5 | 5,374 | 0.153 | 285A |
| 4×240 | 73.1 | 10,569 | 0.0754 | 440A |
| Full specs include 35+ configurations (1.5mm²–800mm²) with PVC/LSZH sheath options. |
Why Shenghua Stands Apart
- 30+ Years of Expertise: Custom solutions for complex projects (e.g., skyscrapers, offshore platforms)
- Rigorous Testing: On-site fire labs validate circuit integrity under BS 7846 and BS 6387 standards
- Global Supply: CE/RoHS-compliant production with 15-day delivery from Shanghai hubs
Cable Structure
Conductor : Class 1,2,5 Flexible Copper Conductor
Screen: Mica tape
Insulation: PVC or LSZH PO
Sheath:PVC: (Optional)
Rated Voltage : 450/750V
Standard :
IEC 60502,60331 IEC 60227, IEC 60331, IEC 601034, IEC60754 GB/T 12706-91 GB306.1-2001, GB/T18380.3-2001
CE, CCC, KEMA
Constructions
Conductor: Circular stranded copper conductor, conforms to IEC 60228 class 2
Insulation: XLPE/A
Inner Covering: LSOH
Sheath: LSOH , black
Note: Insulation color as per standards or customer requirement
Applications
Used for tall building, Hospital, Theatre, Power station, Metro Tunnel or Petrochemical Industry or other special place required for low smoke , zero halogen clean and safe cable.
Standards
International: IEC 60502, IEC 60227 IEC 60331, IEC 601034
China: GB/T 12706-91 GB306.1-2001, GB/T18380.3-2001
Other standards such as BS,DIN and ICEA upon request
Technical data
Rated voltage: 0.6-KV
Max. Conductor Temp.: normal (90°C), short circuit no more than 5 s (the highest temperature of conductor shall no more than 250°C )
Min. Ambient Temp.:The cable shall be pre heated if the ambient temperature is below 0°C
Min. Bending Radius: single core cable 20(d+D)±5%
Multi-core cable 15(d+D)±5%
Certificates
CE, RoHS, CCC, KEMA and more others at request