In high-risk environments such as hospitals, metro tunnels, and petrochemical plants, circuit integrity during fires is non-negotiable. We address this with our FRC 4-Core LSOH Fire Resistant Cables.
Product Information
Model Number:
NH-YJV
Size:
1.5mm² - 800mm²
Rated Voltage:
0.6/1kV
Insulation:
PVC (Polyvinyl Chloride)
Number Of Cores:
1, 2, 3, 4, 5
Temperature:
90°C
Inquiry

In high-risk environments like hospitals, metro tunnels, and petrochemical plants, circuit integrity during fires is non-negotiable. Shanghai Shenghua Power Group Cable addresses this with its FRC 4-Core LSOH Fire Resistant Cables—designed to maintain power transmission even at 1,000°C for 90+ minutes while emitting zero toxic smoke.

 

 

Core Technology: Triple-Layer Fire Defense

  1. Mica Tape Firewall: Wrapped around copper conductors, mica tape withstands 250°C during 5-second short circuits and 750°C+ in prolonged fires, preventing conductor exposure and ensuring circuit integrity 
     
  2. LSOH Insulation & Sheath: Halogen-free materials reduce toxic gas emissions (HCl <0.5%) and smoke density (>60% light transmittance), aligning with IEC 61034-2 and IEC 60754-1 
     
  3. XLPE Thermal Stability: Cross-linked polyethylene insulation enables long-term operation at 90°C, outperforming PVC’s 70°C limit while resisting electrical degradation 
     

Certified Performance for Global Compliance

Shenghua’s cables exceed international safety benchmarks:

  • Standards: IEC 60502, 60331 (fire resistance), 61034 (smoke density), and GB/T 12706 (China) 
     
  • Certifications: CE, RoHS, CCC, and KEMA-tested reliability 
     
  • Fire Ratings: Class ZA/ZB/ZC/ZD flame retardancy and 950°C fire resistance for emergency systems 
     

Installation & Durability Optimized

  • Bending Flexibility: Multi-core cables require only 15× outer diameter bends, easing installation in tight spaces 
     
  • Environmental Resilience: Operates at -0°C to 90°C (preheating below 0°C) and resists chemicals, oils, and mechanical stress 
     
  • Water & Impact Resistance: Withstands sprinkler systems and falling debris during fires—critical for evacuation safety 
     

Applications Where Failure Is Not an Option

  • High-Rise Buildings: Powers fire lifts, smoke control, and emergency lighting (e.g., NH-YJV32 variant) 
     
  • Power Stations & Petrochemical Plants: Ensures uninterrupted operation of critical control systems 
     
  • Metro Tunnels: LSOH properties aid visibility during evacuations 
     

Technical Specifications

Cross-Section (mm²)Outer Diameter (mm)Weight (kg/km)Max. DC Resistance (Ω/km)Current Rating (Air)
4×1.514.424112.120A
4×12052.55,3740.153285A
4×24073.110,5690.0754440A
Full specs include 35+ configurations (1.5mm²–800mm²) with PVC/LSZH sheath options.    

 

Why Shenghua Stands Apart

  • 30+ Years of Expertise: Custom solutions for complex projects (e.g., skyscrapers, offshore platforms) 
     
  • Rigorous Testing: On-site fire labs validate circuit integrity under BS 7846 and BS 6387 standards 
     
  • Global Supply: CE/RoHS-compliant production with 15-day delivery from Shanghai hubs 
     


Cable Structure

Conductor : Class 1,2,5 Flexible Copper Conductor
Screen: Mica tape
Insulation: PVC or LSZH PO
Sheath:PVC: (Optional)
Rated Voltage : 450/750V

 

Standard :

IEC 60502,60331 IEC 60227, IEC 60331, IEC 601034, IEC60754 GB/T 12706-91 GB306.1-2001, GB/T18380.3-2001

CE, CCC, KEMA

Constructions

Conductor: Circular stranded copper conductor, conforms to IEC 60228 class 2

Insulation: XLPE/A

Inner Covering: LSOH

Sheath: LSOH , black

Note: Insulation color as per standards or customer requirement

 

Applications

Used for tall building, Hospital, Theatre, Power station, Metro Tunnel or Petrochemical Industry or other special place required for low smoke , zero halogen clean and safe cable.

 

Standards

International: IEC 60502, IEC 60227 IEC 60331, IEC 601034

China: GB/T 12706-91 GB306.1-2001, GB/T18380.3-2001

Other standards such as BS,DIN and ICEA upon request

 

Technical data

Rated voltage: 0.6-KV

Max. Conductor Temp.: normal (90°C), short circuit no more than 5 s (the highest temperature of conductor shall no more than 250°C )

Min. Ambient Temp.:The cable shall be pre heated if the ambient temperature is below 0°C

Min. Bending Radius: single core cable 20(d+D)±5%

Multi-core cable 15(d+D)±5%

 

Certificates

CE, RoHS, CCC, KEMA and more others at request

Recommended products
Electrical Fire Resistant Cable For Buildings House Wiring NYY NYCY Shenghua Cable
Electrical Fire Resistant Cable For Buildings House Wiring NYY NYCY Shenghua Cable
Shanghai Shenghua delivers IEC 60502-certified NYY-FE fire resistant cables with XLPE insulation & LSZH sheathing for high-rise safety, zero-toxicity, and 90+ minute circuit integrity.
CU / Mica Tape Fire Resistant Cable For Sprinkler Smoke Control System NH-YJV
CU / Mica Tape Fire Resistant Cable For Sprinkler Smoke Control System NH-YJV
Engineers at Shanghai Shenghua Power Group Cable have engineered CU/Mica Tape Fire Resistant Cables to outlast infernos—ensuring critical systems keep operating even at 950°C for 90+ minutes.
logo
Address: No.7577 of Hunan RD., Pudong Nwe District 201314, Shanghai, ChinaMobile phone: +86-15901866124Telephone: 86-21-58176629Email: shenghuacablegroup@gmail.com
Product Series
XLPE Insulated Power Cable
Armoured Electrical Cable
PVC Insulated Cable
Electrical Cable Wire
Product Series
Low Smoke Zero Halogen Cable
Bare Conductor
Fire Resistant Cable
Aerial Bundled Cable
Company Profiles
About Us
Contact Us
Blogs
News
Cases

Copyright © 2026 上海胜华电线电缆有限公司 Ltd. All Rights Reserved. POWERED BY WEIMOBTRADE