In mining and tunneling operations where fires release lethal toxic fumes, traditional cables become death traps—releasing hydrogen chloride and dioxins that cause 60% of fire-related fatalities
. Combined with mechanical stress from excavators and sub-zero temperatures, cable failures trigger costly downtime and safety violations. Shanghai Shenghua Power Group Cable solves these challenges with its MCDP Low Smoke Zero Halogen (LSZH) Rubber Sheathed Cables, engineered to deliver life-saving toxicity reduction, arctic-grade flexibility, and flame-retardant reliability for 0.38/0.66KV to 6/10KV mining equipment.
Life-Saving LSZH Technology:
Arctic-to-Desert Resilience:
Crush-Proof Power Delivery:
Shenghua’s MCDP series complies with:
| Model | Rated Voltage | Conductor Configuration | LSZH Sheath Thickness | Temp Range | Bending Radius |
|---|---|---|---|---|---|
| MCP-0.38/0.66kV | 0.38/0.66kV | 3 Phase + 1 Ground + 3 Ctrl | 4.5mm (16mm²) | -40°C to 65°C | 6× diameter |
| MCPT-1.9/3.3kV | 1.9/3.3kV | 3 Phase + 1 Ground | 6.0mm (95mm²) | -20°C to 90°C | 6× diameter |
| MYPD-3.6/6kV | 3.6/6kV | 3 Phase + 1 Ground | 6.0mm (95mm²) | -40°C to 90°C | 6× diameter |
Insulation Resistance: 350 MΩ·km (16mm²) to 160 MΩ·km (185mm²) at 20°C
Construction:
Conductor: Flexible Class 5 Copper Conductor
Insulation: Rubber Sheath
Screen: Copper Wire Braid Screen / Tinned Copper Wire Screen
Sheath: Low Smoke Low Halogen Rubber
The Advantage Of Low Smoke Low Halogen Rubber
When a fire occurs, it can reduce the toxic gases, protect people's lives
Brief introduction
1. Rated voltage of the cables is divided into 6 grades, which is 0.3/0.5kV, 0.38/0.66kV, 1.9/3.3kV, 3.6/6kV, 6/10kV.
2. There are allowed long-term working temperatures of the cable conductor. For the cable of U(M)CPT-0.66/1.14, U(M)CPJB-0.66/1.14, U(M)CPJR-0.66/1.14 and 1.9/3.3kV, 3.6/6kV, 6/10kV, the temperature is 90℃; for the other, it is 65℃.
3. Minimum bending radius: For the cable of U (M)CPJB-0.66/1.14, U(M)CPJR-0.66/1.14, it is 15 times of the cable diameter; for the others, it is 6 times of the cable diameters.
4. The grounding wire should be well connected with the earth.
5. The cable should be prevented from exposing to the sunshine for a long time.
Implemented standard
1 For the non-spread combustion cable, implement GB12972
2 For the flame-retardant cable, implement MT818
3 For the special mining cable(with bigger cross-section and higher voltage), implement the enterprise standard.
Type and Name: