Triple-Shield Engineering for Brutal Environments
-
Military-Grade EMI/RFI Shielding:
- Aluminum-Plastic Composite Tape + Copper Braid (DJYP3VP3-32 variant) provides 85 dB attenuation at 30 MHz, neutralizing interference from 10kV transformers and VFDs in steel mills
- Individual & Overall Shielding (e.g., DJYP3VP3) prevents cross-talk in 38-core bundles, enabling simultaneous 10A power and 1kHz sensor signals without distortion
- Aluminum-Plastic Composite Tape + Copper Braid (DJYP3VP3-32 variant) provides 85 dB attenuation at 30 MHz, neutralizing interference from 10kV transformers and VFDs in steel mills
-
Arctic-to-Desert Resilience:
- 90°C Continuous Rating (vs. industry-standard 70°C) sustains insulation resistance >12 MΩ·km in turbine halls where ambient temps hit 65°C+
- -40°C Cold Flexibility prevents sheath cracking in Siberian substations, withstanding 500,000+ bend cycles in cable trays
- 90°C Continuous Rating (vs. industry-standard 70°C) sustains insulation resistance >12 MΩ·km in turbine halls where ambient temps hit 65°C+
-
Mechanical Fortification:
- Steel Wire Armor (DJYVP3-32) withstands 8-ton crushing loads—validated in Shanghai port crane collisions
- 6× Bend Radius (e.g., 20.1mm OD for 19-core) enables tight routing in congested PLC panels, cutting installation time by 40%
- Steel Wire Armor (DJYVP3-32) withstands 8-ton crushing loads—validated in Shanghai port crane collisions
Certified for Global Hazardous Zones
Shenghua’s tray cables comply with:
- IEC 60228 & GB9330: Flame retardancy (IEC 60332) and 3kV dielectric strength
- CE/RoHS/KEMA: Halogen-free materials (Cd <0.01%, Pb <0.1%) and EMI immunity validation
- ISO 9001/OHSAS 18001: Safety protocols for oil/gas installations
Technical Specifications: Shenghua Tray Cable Range
| Model | Shielding Type | Armor | Cores | Temp Range |
| DJYVP3 | Overall tape | None | 1-38 | -40°C to 90°C |
| DJYP3VP3 | Individual + overall tape | None | 1-38 | -40°C to 90°C |
| DJYVP3-32 | Overall tape | Steel wire | 1-19 | -40°C to 90°C |
| DJYP3VP3-32 | Individual + overall tape | Steel wire | 1-19 | -40°C to 90°C |
Voltage Rating: 300/500V to 600/1000V DC • Bending Radius: 6× OD (12× for armored)
Proven Applications in Critical Infrastructure
- Nuclear Plant SCADA Systems: DJYP3VP3-32 cables maintained signal accuracy amid 110kV switchgear EMI in Guangdong Phase III
- Offshore Wind Farms: DJYVP3-22 resisted salt corrosion for 8+ years in North Sea turbines
- Automotive Robotics: 38-core DJYP3V eliminated data loss in BMW’s welding lines despite 15kA arc flashes
Why Global Engineers Trust Shanghai Shenghua
-
Zero-Defect Manufacturing:
- AI-Powered Shielding Integrity Checks: Laser scans verify tape overlap uniformity (±0.1mm), eliminating EMI gaps
.5
- 100% Hi-Pot Testing: 3.5kV AC stress tests validate insulation integrity for KEMA compliance
- AI-Powered Shielding Integrity Checks: Laser scans verify tape overlap uniformity (±0.1mm), eliminating EMI gaps
-
Rapid Customization & Support:
- 24-Hour Quoting: Bespoke cores (1-38), voltages (300V-1000V), and DIN/BS certifications
- 12-Month Warranty: Proactive replacements for IEC deviations—backed by PICC insurance
- 24-Hour Quoting: Bespoke cores (1-38), voltages (300V-1000V), and DIN/BS certifications
-
Global Deployment Legacy:
- Supplied 1,200km+ cables for China’s Three Gorges Dam distribution network (38-core bundles)
- 36+ Patents for armor-weaving and XLPE insulation tech
- Supplied 1,200km+ cables for China’s Three Gorges Dam distribution network (38-core bundles)
Application
This product applies for connecting wire of electric appliance,apparatus
or computer,used in distribution eqwipments with rated voltage up to
and including A.C.450/750V or D.C.1000V.
Character and Relevant Parameters
1. Long-term service temperature of the cable conductor: 90°C
2. Rated voltage: 300/500V,450/750V ,600/1000V.
3. Cable lying temperature ≥ 0°C
4. Cores(pair/triple): 1~19
5. Minimun bending radius:≥ out diameter of cable 6 times
Use condition
The cable is approved to operate upon fixed-installation or
moveable using in ambient temperature from -40 ℃ to 50 ℃ ,
relative humidity not larger than 80%and operating temperature
of core not higher than 70 ℃ as well as avoiding direct high-
temperature radiation or contact.
The temperature shall never less than 0℃ when the cable being
laid.
Permissible bending radius:not less than 6 times of overall
diameter for unarmored cable;not less than 12 times of overall
diameter for armored or screened cable;not less than 6 times of
overall diameter for screened flexible cable.