Blogs /
Shielded instrumentation cables for industrial monitoring

Shielded instrumentation cables for industrial monitoring

Shenghua's Shielded Instrumentation Cable: Critical Components for Industrial Monitoring Systems For industrial monitoring systems, signal transmission reliability directly determines the accuracy and stability of process control. As the core signal transmission carrier, the quality of shielded instrumentation cables determines whether weak process signals (such as 4-20mA, thermocouple, RTD signals) can be transmitted without interference. Shenghua, as a professional cable manufacturer, has been deeply involved in the R&D and production of instrumentation cables for many years, and its product series fully cover industrial monitoring scenarios, from conventional signal transmission to special environments, which can meet the diversified needs of project procurement. Shielding Technology: Multi-layer Protection to Cope with Complex Electromagnetic Environment The core value of shielded instrumentation cables lies in anti-interference performance. Shenghua adopts a variety of shielding combinations to target different interference sources: - Foil shielding (aluminum foil + drain wire): For high-frequency electromagnetic interference, the coverage rate of 100% effectively isolates high-frequency clutter and is suitable for signal transmission in electronic equipment-intensive areas. - Copper wire braided shielding: For low-frequency magnetic field interference, high-density braiding (copper or tinned copper) provides both electromagnetic shielding and physical protection, with strong tensile strength. - Composite shielding (foil + braid): Taking into account high-frequency and low-frequency interference, it is suitable for complex industrial environments such as substations and chemical plants, ensuring stable signal transmission in strong electromagnetic fields. Shielding coverage is directly linked to anti-interference effect. Shenghua can customize the braiding density according to project needs (usually 85% - 95%), which balances flexibility and shielding performance. Armor Structure: Adapt to Harsh Installation Environments Industrial sites often face mechanical stress, moisture, rodent bites and other challenges. Shenghua's armored instrumentation cables provide targeted protection: - Steel tape armor (STA): It adopts double-layer steel tape longitudinal wrapping, which has strong compressive and anti-piercing capabilities. It is suitable for direct burial or tray laying, and prevents external mechanical damage. - Steel wire armor (SWA): Galvanized steel wire braiding or stranding, which has both tensile and anti-puncture properties, and is suitable for overhead or underwater laying, as well as scenarios requiring heavy load resistance. - Aluminum tape armor (ATA): Lighter weight, corrosion-resistant, suitable for occasions with certain anti-puncture requirements and weight limit, such as indoor trays and cable trenches. Armor materials are usually matched with sheath materials to further enhance environmental adaptability, such as steel tape armor + PE sheath to cope with humid and corrosive environments. Material Selection: Balance of Conductor, Insulation and Sheath Shenghua's instrumentation cables adhere to the principles of high purity, durability and environmental protection in material selection: - Conductor: It is made of high-purity oxygen-free copper (TU1) or tinned copper, with low resistance and good conductivity. Tinned copper has better corrosion resistance and is suitable for humid or chemically corrosive environments. It meets the Class 1/2 solid or stranded conductor standards in GB/T 3956, ensuring the flexibility and connection reliability of the cable. - Insulation: The main materials are PVC, PE, XLPE: - PVC: Cost-effective, oil-resistant and flame-retardant, suitable for conventional temperature environments (70℃). - PE: Low dielectric constant, low capacitance, suitable for high-frequency signal transmission, with good moisture resistance. - XLPE: High temperature resistance (90℃), high mechanical strength, suitable for high-temperature industrial scenarios, improving current carrying capacity and service life. - Filling: Non-hygroscopic material (such as PP rope) is used to maintain the roundness of the cable and enhance structural stability. - Sheath: According to the environment, choose PVC (ordinary wear-resistant), PE (corrosion-resistant and moisture-proof), LSZH (low smoke and halogen-free, flame-retardant, suitable for indoor and densely populated places), PUR (wear-resistant and oil-resistant, suitable for moving occasions). Compliance and Certification: The Foundation of Project Procurement Shenghua's shielded instrumentation cables strictly comply with domestic and international standards to ensure project compliance: - National standard: In line with GB/T 9330 "Plastic Insulated Control Cables and Instrumentation Cables", the electrical performance and structural dimensions meet the specifications. - International standards: Refer to IEC 60228 (conductor), IEC 60332 (flame retardant), IEC 60754 (halogen acid gas), ISO 6722 (automotive scenario, if applicable) and other standards to support export projects. - Certification: Products have obtained CCC (compulsory certification), CE (EU market), RoHS (environmental protection) and other certifications, and can provide type test reports, flame retardant grade certificates (such as ZA/ZB/ZC), and the flame retardant performance meets the requirements of GB/T 18380. Application Scenarios: Full Coverage of Industrial Monitoring Shenghua's shielded instrumentation cables are widely used in the following scenarios: - Chemical/petrochemical: Intrinsically safe explosion-proof design (can be equipped with intrinsic safety circuit) to transmit temperature, pressure, flow signals and adapt to corrosive and flammable and explosive environments. - Power/electric power: Used for signal transmission in substations and power plants to resist electromagnetic interference from high-voltage equipment and ensure the stability of monitoring systems. - Metallurgy/steel: High temperature resistance and wear resistance, suitable for harsh environments such as high temperature and dust. - Water treatment/environmental protection: Moisture-proof and corrosion-resistant, long-term reliable operation in humid and corrosive media. - Construction/building intelligence: Low-smoke and halogen-free sheath, used for HVAC, lighting control and other systems to meet fire protection requirements. Procurement Suggestions: Customized Solutions for Different Needs When purchasing shielded instrumentation cables, projects need to focus on the following points, and Shenghua can provide customized support: 1. Interference source matching: High-frequency interference -> foil shielding; low-frequency magnetic field -> braided shielding; complex environment -> composite shielding. 2. Laying mode: Direct burial/heavy load -> steel tape/steel wire armor; tray/indoor -> no armor or aluminum tape armor. 3. Environmental conditions: High temperature -> XLPE insulation; humidity/corrosion -> PE/PUR sheath; indoor/fire protection -> low-smoke halogen-free sheath. 4. Signal type: Weak signals (thermocouple, RTD) -> high shielding coverage; analog/digital signals -> low capacitance insulation (PE/XLPE). As a professional manufacturer, Shenghua can also provide customized services such as special conductor size, core number, and sheath color according to project drawings to ensure that the cable is perfectly adapted to the mon

News Details

Industrial monitoring depends on signals transmitted between sensors, instruments, and control equipment. However, choosing the wrong cable can complicate installation and troubleshooting. A cable must be compatible with the signal type, route, electrical environment, and connection method.

Shenghua Cable Group produces instrumentation cables along with power, control, and other specialty cables. Its shielded instrumentation cable product line offers various options for conductor, insulation, shielding, and armor.

For EPC contractors, equipment manufacturers, and distributors, a clear cable specification helps convert these options into an accurate purchasing decision.

 

Start with the Signal and Equipment

First, identify what the cable will connect. Temperature sensors, pressure transmitters, and control devices may require different conductor arrangements and electrical characteristics.

Key application information includes:

  • Instrument and controller types

  • Signal type and operating voltage

  • Cable routing length

  • Required pairs, triads, or cores

  • Conductor size

  • Terminal and connector requirements

  • Nearby motors, drives, or power circuits

For digital communications, confirm the cable requirements of the protocol. General instrumentation cables should not be regarded as substitutes for all industrial network cables.

Similarly, for analog circuits, check the allowable cable resistance and other relevant electrical limits for the equipment.

 

Individual Shields and Overall Screens

Shielding helps reduce unwanted electrical interference. However, individual shields and overall screens serve different functions.

The overall shield surrounds the entire cable assembly. Individual shields enclose separate pairs or triads, helping to reduce interference between signal groups within the cable.

Where multiple sensitive signals share the same route, it may be worth considering both individual and overall shielding. For simpler connections, an overall shield may meet the approved specification.

Shenghua provides overall screened instrument cable as part of its instrumentation product line. Purchasers should confirm the shielding material, drain wire, coverage requirements, and termination method.

The performance of the shield also depends on the installation. Therefore, follow the grounding and bonding plan of the system designer rather than applying a single grounding rule to all circuits.

 

Specify Pairs, Triads, and Core Identification

Merely stating the number of cores may leave room for ambiguity. For example, six cores do not necessarily represent the same structure as three twisted pairs.

Clearly state the required grouping in the cable schedule. Also confirm whether each pair or triad requires its own shielding and identification.

Consistent numbering or color coding helps installers connect the correct circuits. It also facilitates future maintenance.

When ordering multiple cable sizes, use the project's agreed identification scheme. This reduces the chance of confusing cables that look similar during installation.

 

Choose Conductor and Insulation Materials

The instrumentation cable options published by Shenghua include copper or tinned copper conductors and PE, XLPE, or PVC insulation, depending on the structure.

When selecting a conductor, consider its size, strand class, resistance, and compatibility with the terminal. Fine-stranded wires can improve flexibility, but flexibility alone does not indicate suitability for repeated movement.

Next, evaluate the insulation based on the working voltage, temperature, and signal requirements. Where capacitance or other electrical properties affect the connected equipment, include the limits in the specifications.

Request a datasheet covering the exact cable model proposed. The temperature limits and bending requirements may vary between different structures within the same product family.

 

Determine If Armor Is Needed

The armor provides mechanical protection. Shielding addresses electrical interference. Therefore, one should not be assumed to replace the other.

Armored instrumentation cables may be suitable for routes exposed to impact, pressure, or other mechanical hazards. Protected indoor routes may allow for non-armored designs, subject to project specifications.

Shenghua lists optional steel wire or steel tape armor for certain instrument cable structures. Before selecting the armor, review:

  • Cable routing and support method

  • Expected mechanical loads
  • Overall diameter and weight
  • Required bending space
  • Pulling conditions
  • Compatibility of cable glands and terminations
  • Also confirm any bonding requirements for the armor. These details should be finalized before production and the purchase of accessories.

     

    Select a Sheath Suited to the Installation

    The outer sheath must be compatible with the environment surrounding the cable. Describe the indoor or outdoor use, humidity, sunlight, oil, chemicals, and installation temperature in the inquiry.

    For chemical exposure, identify the substance and expected contact conditions. General requests for "chemical resistance" may not provide enough information for material selection.

    Similarly, if the project requires low smoke, halogen limits, or flame retardancy, the required tests should be specified separately.

    For cable tray installations, review the proposed

    shielded instrumentation tray cable

    . Confirm its suitability for the project's installation rules and target market prior to approval.

     

    Agree on Inspection and Supporting Documentation

    A technical offer should describe what the manufacturer will supply and how acceptance will be conducted.

    Depending on the specifications, the inspection plan may cover conductor resistance, insulation resistance, voltage testing, dimensions, core identification, and shielding continuity.

    Where signal performance depends on capacitance or shielding characteristics, agree on the required measurements and supporting evidence.

    Request documentation for the offered model, including:

    • Cable construction drawing

  • Technical data sheet
  • Relevant test reports
  • Inspection records
  • Product approval documents (where required)
  • Packing and drum schedule
  • The scope of the certificate should match the cable being purchased. Also agree on any third-party inspections prior to the start of manufacturing.

     

    Plan Lengths and Repeat Orders

    Cable lengths should be based on the installation plan. Review the route sections, spare allowances, pulling equipment, and storage limits prior to confirming the drum size.

    Clear drum labels help the receiving team identify each item against the cable schedule. Agree on product codes, meter markings, length tolerances, and packaging requirements.

    For repeat orders, retain the approved drawings and specification revisions. Request the supplier to confirm any proposed material or structural changes prior to production.

    This provides consistent reference for OEMs and distributors when reordering the same cable.

     

    Source Instrumentation Cable from Shenghua

    Established in 1997,

    Shenghua Cable Group

    specializes in research, development, and manufacturing of wires and cables. Its product portfolio includes instrumentation, control, power, and other application-specific cables.

    For a quotation, please provide signal requirements, conductor size, pair or core configuration, voltage, shielding, armor, sheath, applicable standards, quantity, and delivery schedule.

    Where available, include equipment drawings or existing cable specifications. These details help Shenghua review the required structure and prepare a project-specific proposal.

    Share to:
    facebook
    line
    Whatsapp
    Pinterest
    Tumblr
    Linkedin